Description: DESCRIPTION Woodpecker Endo Gold Endomotor is mainly used in Endodontic treatment.During root canal preparation procedure,it is used to mold & clean the root canal.ADVANTAGES:OLED displaya) Customized program sequence number 1-9, totally 9 programs b) Operation mode c) Battery consumption d) Set speed e) Set torque f) File system g) Operation mode h) Torque setting i) Real-time torqueProtective function of automatic reverseDuring operation, if the load value exceeds the preset torque value, the file rotation modFeaturesWireless handpiece enables more convenient operation.Adopt real-time feedback technology and dynamic torque control,effectively preventing needle breakage.Storage of 9 user-defined modes allows invocation at any time. Under each mode, Continuous Rotation Mode, Reciprocating Motion Mode, and Reverse Rotation are for options.Key SpecificationsBatteryLithium battery in handpiece: 3.7V /1400mAhPower adapterInput: ~100V-240V 50Hz/60Hz 0.4A MaxOutput: DC5V/1ATorque0.6Ncm-5.0Ncm(6mNm ~ 50mNm)Rotate speed100rpm~1000rpmEnvironment temperature+5°C ~ +40°CRelative humidity30% ~ 75%Atmospheric pressure70kPa ~ 106kPaStorage:This equipment should be stored in a room where the relative humidity is 10% ~ 93%, atmospheric pressure is 70kPa to106kPa, and the temperature is -20°C ~ +55°C.Avoid the storage in a too hot condition. High temperature will shorten the life of electronic components, damage battery, reshape or melt some plastic.Avoid the storage in a too cold condition. Otherwise, when the temperature of the equipment increases to a normal level, there will be dew that will possibly damage PCB board.Oiling of contra-angle:Only the original oil injection nozzle can be used for oiling of contra-angle. After disinfection of contra-angle and before sterilization, oiling should be conducted under high pressure and high temperature.screw the injecting nozzle into jet of oil bottle. (Around 10 circles)Plug the nozzle into the end part of contra-angle, and then grease the contra-angle for 2-3s till the oil flow out of contra-angle head part.Vertically place the end part of contra-angle or tilt the contra-angle to let go the redundant oil under gravity.Packaging1 x Endomotor Handpiece1 x Charging Base1 x Contra-angle1 x Power Adapter1 x LubricatorInstructional Manual Direction to UseStarting and StoppingSelecting memorySpeed setting, torque setting, and operation mode settingUnder standby state, short press key to enter speed setting, torque setting, and operation mode setting interfaces.In setting interface, it will automatically back to Standby interface after 5s without operation. Press key to enter Standby interface. WarrantyManufacturer/Importer warranty of 1 Year against manufacturing defectService and Warranty are handled by the manufacturer/importer directly for this product Dentalkart will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/ImporterDentalkart and the Buyer acknowledge that the Products purchased/usedare a subject matter of original Manufacturer/Importer’s warranties onlyAny or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Dentalkart may assist the customer in registering a request to get the Product replaced or serviced. The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be. FAQsQ1.When we need to charge the battery of Endomotor?If the battery icon turns into display that as the picture shown,it indicates that the battery capacity is very low. Please charge.When the battery capacity is the too low, the device may indicate “Low Battery!” and automatically power off.Q2.How to make sure that my Endomotor is charging?Connect the power adapter with the base. Confirm that it is well connected, and then place the handpiece into the base. If the indicator light on base turns yellow, it indicates that it is charging. If the indicator light on base turns green, it indicates that the battery capacity is enough, and there is no need to charge.After charging, please unplug the power adapter.Q3.How to switch-off the Endomotor after use?In Standby Interface, the handpiece would automatically shut down after 3 minutes without any button-pressing operation. The handpiece will also automatically shut down while it is put into the charging base. In Standby Interface, long press setting key , and then long press Adjusting key, finally the device will automatically shut down 2s later.Disclaimer "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item." Business Information Name- AK International City - Jacksonville State- Florida Contact Number- +1 (904) 425-9702
Price: 499.99 USD
Location: Jacksonville, Florida
End Time: 2024-08-26T17:51:47.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money back or replacement (buyer's choice)
Non-Domestic Product: No
Model: ENDOGOLD
Modified Item: No
Custom Bundle: No
MPN: Does Not Apply
Brand: Woodpecker
Intended Use/Discipline: Dentistry