Description: Lambda / TDK GEN60-40 AT417589570 Programmable DC Power Supply 0-60V 0-40AItemMake: Lambda / TDK / EMIModel: GEN60-40 Options: IEMD, 3P208Item Specifics/Condition Tested Good Description Description The Genesys™ Programmable DC Power Supply Series provides high power density (from 750W to 15kW) with a complete set of user-friendly interfaces in bench-top or rack-mount profiles and offers Output voltages from 6V to 1500V at Output currents up to 1000A using worldwide AC inputs (with built-in Power Factor Correction). Multiple remote interfacing methods are available including the built-in Remote Analog Program/Monitor (5V/10V) and Remote Digital (RS-232/RS-485) Interfaces along with the optional LAN (LXI 1.5), USB (2.0), IEEE (488.2 compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces. All models are CE and UKCA marked in accordance with the Low Voltage, EMC and RoHS Directives, have worldwide Safety Agency approvals (UL/cUL/IEC/EN 61010-1) and offer a five year warranty. GenesysTM power supplies are wide output range, high performance switching power supplies. The GenesysTM series is power factor corrected and operates from worldwide AC voltage range. Output voltage and current are continuously displayed and LED indicators show the complete operating status of the power supply. The front panel controls allow the user to set the output parameters, the protection levels (Over-Voltage protection, UnderVoltage limit and Foldback) and Preview the settings. The rear panel includes the necessary connectors to control and monitor the power supply operation by remote analog signals or by the built-in serial communication (RS-232/RS-485). LAN,IEEE and USB programming and Isolated-Analog programming/monitoring are optional. Features include: New: Auxiliary Outputs, 5V, 0.2A; 15V, 0.2A For Increased System Control Functionality New: RoHS Compliant High Power Density 2.4kW in 1U Wide Range of popular worldwide AC inputs, 1Ø (230VAC) & 3Ø (208VAC) Active Power Factor Correction (Single-Phase & Three-Phase AC Input) Output Voltage up to 600V, Current up to 300A Built-in RS-232/RS-485 Interface Standard Global Commands for Serial RS-232/RS-485 Interface Auto-Re-Start / Safe-Start: user selectable Last-Setting Memory High Resolution 16 bit ADCs & DACs Low Ripple & Noise Front Panel Lock selectable from Front Panel or Software Reliable Encoders for Voltage and Current Adjustment Constant Voltage/Constant Current auto-crossover Parallel Operation with Active Current Sharing; up to four identical units. Advanced Parallel Master / Slave. Total Current is Programmed and Measured via the Master. Independent Remote ON/OFF and Remote Enable/Disable External Analog Programming and Monitoring (user selectable 0-5V & 0-10V) Reliable Modular and SMT Design 19” Rack Mount capability for ATE and OEM applications Optional Interfaces Isolated Analog Programming and Monitoring Interface (0-5V/0-10V & 4-20mA) IEEE 488.2 SCPI (GPIB) Multi-Drop LXI Compliant LAN USB Interface LabView and LabWindowsTM drivers Five Year Warranty Applications GenesysTM power supplies have been designed to meet the demands of a wide variety of applications. System Designers will appreciate new, standard, remote programming features such as Global commands. Also, new high-speed status monitoring is available for the RS-485 bus. Test Systems using the IEEE-488 bus may achieve significant cost savings by incorporating the Optional IEEE MultiDrop Interface for a Master and up to 30 RS-485 Multi-Drop Slaves. Then up to 30 Slaves may be equipped with the less expensive Optional RS-485 Multi-Drop (MD) interface. Higher power systems can be configured with up to four 2.4kW modules. Each module is 1U with zero space between them (zero stack). Flexible configuration is provided by the complete GenesysTM Family: 1U 750W Half-Rack, 1U 750W/1500W/2400W 2U 3.3kW/5kW, 3U 10/15kW Full-Rack. All are identical in Front Panel, Rear Panel Analog, and all Digital Interface Commands. OEM Designers have a wide variety of Inputs and Outputs from which to select depending on application and location. Front Panel Description ON/OFF Switch Air Intake allows zero stacking for maximum system flexibility and power density. Reliable encoder controls Output Voltage, Address, OVP and UVL settings. Volt Display shows Output Voltage and directly displays OVP, UVL and Address settings. Reliable encoder controls Output Current, sets Baud rate and Advanced Parallel mode. Current Display shows Output Current and displays Baud rate. Displays total current in Parallel Master/Slave Mode Function/Status LEDs: Alarm Fine Control Preview Settings Foldback Mode Remote Mode Output On Pushbuttons allow flexible user configuration Coarse and Fine adjustment of Output Voltage/Current and Advanced Parallel Master or Slave Preview settings and set Voltage/Current with Output OFF, Front Panel Lock Parallel Master/Slave Set OVP and UVL Limits Set Current Foldback Protection Go to Local Mode and select Address and Baud rate Output ON/OFF and Auto/Safe Re-Start Mode Rear Panel Description Remote/Local Output Voltage Sense Connections. DIP Switches select 0-5V or 0-10V Programming and other functions. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor and other functions. RS-485 OUT to other Genesys™ Power Supplies. RS-232/RS-485 IN Remote Serial Programming. Output Connections: Rugged busbars (shown) for up to 100V Output; wire clamp connector for Outputs >100V. Exit air assures reliable operation when zero stacked. Input: 230VAC Single Phase, 208 VAC Three Phase, 50/60 Hz AC Input Connector: Phoenix P/N: FRONT-4-H-7.62. Optional Interface Position for IEEE 488.2 SCPI (shown) or Isolated Analog, LAN or USB Interface. Auxiliary Output Voltage Connector. Phoenix P/N IMC1.5/7-ST-3.81 GenesysTM 2.4kW Specifications INPUT CHARACTERISTICS GEN 60-40 Input voltage/freq. (*3): Single Phase,230V models: 170~265Vac, 47~63Hz, 3-Phase, 208Vac models: 170~265Vrms , 47~63Hz Maximum Input current at 100% load: 1-Phase,230V models: 16.3 Arms 3-Phase, 208V models: 9.8 Power Factor (Typ): Single Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208 Vac, rated output power. Efficiency (*4): 88% Inrush Current (5): Single-Phase and 3-Phase 208V models: Less than 50A Hold up time (CV Mode): 10mSec for Single-Phase and 3-phase 208V models, at rated output power. AUXILIARY OUTPUT 15V output: 15V±5%, 0.2A Max load, Ripple & Noise 100mVp-p. Referenced internally to the negative output potential. 5V output: 5V±5%, 0.2A Max load, Ripple & Noise 100mVp-p. Referenced internally to IF_com potential. POWER SUPPLY CONFIGURATION Parallel Operation: Up to Four (4) identical units may be connected in Master/Slave Mode with two wire connection. In Advanced parallel feature, the current of Master Unit, multiplied by number of units connected in parallel, is made available on digital interface and displayed on front panel of Master unit. Remote analog current monitor of the Master is scaled to output current of the Master unit (only). Series Operation: Possible (with external diodes), up to identical 2 units with total output not to exceed +/-600V from chassis ground. ENVIRONMENTAL CONDITIONS Operating temperature: 0~50°C, 100% load. Storage temperature: -20~85°C Operating humidity: 20~90% RH (non-condensing). Storage humidity: 10~95% RH (non-condensing). Vibration: MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface. Shock: Less than 20G , half sine , 11mSec. Unit is unpacked. Altitude: Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp. by 1ºC/100m above 2000m. Non operating: 40000ft (12000m) RoHS Compliance: Complies with the requirements of RoHS directive. EMC Applicable Standards: Nil ESD: IEC1000-4-2. Air-disch.-8kV, contact disch.-4kV Fast transients: IEC1000-4-4. 2kV Surge immunity: IEC1000-4-5. 1kV line to line, 2kV line to ground Conducted immunity: IEC1000-4-6, 3V Radiated immunity: IEC1000-4-3, 3V/m Magnetic field immunity: EN61000-4-8, 1A/m Voltage dips: EN61000-4-11 Conducted emission: EN55022A, FCC part 15-A, VCCI-A. Radiated emission: EN55022A, FCC part 15-A, VCCI-A. SAFETY Applicable standards: CE Mark, UL60950,EN60950 listed. Vout≤40V:Output is SELV, IEEE/Isolated analog are SELV. 40 Price: 3039.75 USD Location: Farmingdale, New Jersey End Time: 2024-03-09T12:56:12.000Z Shipping Cost: N/A USD Return shipping will be paid by: Buyer All returns accepted: Returns Accepted Item must be returned within: 30 Days Refund will be given as: Money Back Return policy details: MPN: GEN60-40 model: Lambda / TDK GEN60-40 AT417589570 Programmable DC Brand: Lambda / TDK / EMIProduct Images
Item Specifics