Description: CE CONTEC MS200 NIBP SIMULATOR DYNAMIC BLOOD PRESSURE SIMULATOR,LCD DISPLAY Product overview MS200 NIBP Simulator is a multi-purpose test instrument for use with oscillometric Non-Invasive Blood Pressure(NIBP) Monitors. The appearance is concision ,operation is simple and convenient,with its internal pump, the Simulator can generate pressures up to 400 mmHg (53.3 kPa).The Simulator provides dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing.You can quickly and exact analyse different NIBP Monitors. Main features Provides pressure gauge testing,pressure leak testing,relief valve testing functions . Build-in pump provides pressure source with leak and pressure relief tests NIBP simulations for both arm and wrist cuffs. Provides adult,neonate, eight variations patients conditions,user-defined simulations. Provides arrhythmias,respiratory artifact simulations. Built-in air chamber to simulate adult and neonate cuff. 65k colors,4.3" LCD display. Technical index Pressure measurement Units:mmHg,kPa,cmH2O,inH2O,psi Range:0mmHg-400mmHg Resolution:1 mmHg,0.1 kPa,1 cmH2O,1 inH2O,0.1 psi Accuracy:0-300 mmHg:±0.5% of reading ±1 mmHg; 301-400 mmHg:±2%of reading Pressure Generator Static Pressure Range:50 mmHg-400 mmHg Resolution:1mmHg Difference between target pressure and actual pressure :±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc Internal leak rate <2 mmHg per minute, with a minimum volume of 300 cc Pressure Leak Test Pressure generate up to 400 mmHg (53.3 kPa) with internal pump.The screen always show the peak pressures and the real-time pressures.Leak rate displayed after 10 seconds. Pressure Relief Test Pressure generate up to 400 mmHg (53.3 kPa) with internal pump,Displays peak pressure. Standard BP Simulations Preset blood pressure: 1#: BP: 120/80(93) HR: 80 Pulse Volume: 0.68 2#: BP: 150/100(116) HR: 80 Pulse Volume: 0.65 3#: BP: 200/150(166) HR: 80 Pulse Volume: 0.60 4#: BP: 255/195(215) HR: 80 Pulse Volume: 0.55 5#: BP: 60/30(40) HR: 80 Pulse Volume: 0.75 6#: BP: 80/50(60) HR: 80 Pulse Volume: 0.71 7#: BP: 100/65(76) HR: 80 Pulse Volume: 0.69 Patient Conditions BP Simulations Healthy: BP: 120/80(93) HR:75 Pulse Volume: 0.68 Weak Pulse: BP: 110/80(90) HR:95 Pulse Volume: 0.50 Mild Exercise: BP: 140/90(106) HR:120 Pulse Volume: 1.00 Strenuous Exer: BP: 140/90(106) HR:162 Pulse Volume: 1.40 Obese: BP: 120/80(93) HR:90 Pulse Volume: 0.50 Geriatric: BP: 150/110(123) HR:95 Pulse Volume: 0.40 Tachycardia: BP: 120/105(110) HR:130 Pulse Volume: 0.40 Bradycardia: BP: 120/60(80) HR:45 Pulse Volume: 1.10 Arrhythmia Simulations Premature Atrial Contract 1,Premature Atrial Contract 2,Premature Ventricular Contract,Atrial Fib and PVCs Respiratory Artifacts Spontaneous Breathing 1,Spontaneous Breathing 2,Spontaneous Breathing 3,Controlled Ventilation Neonate simulations User can select External or Internal Neonate; 1#: BP: 35/15 HR: 120bpm Pulse Volume: 0.11 2#: BP: 60/30 HR: 120bpm Pulse Volume: 0.10 3#: BP: 80/50 HR: 120bpm Pulse Volume: 0.10 4#: BP: 100/70 HR: 120bpm Pulse Volume: 0.10 Wrist simulations 1#: BP:120/80(93) HR: 80bpm Pulse Volume: 0.50 2#: BP:160/100(120) HR: 80bpm Pulse Volume: 0.50 3#: BP:80/55(63) HR: 80bpm Pulse Volume: 0.50 User-Defined simulations Allows the operator to define blood pressure simulations. Systolic(mmHg) 20-250 Diastolic(mmHg) 10-200 Heart Rate,(bpm) 30-250 Pulse Volume,(cc) 0.1-2.4 Simulant characteristics The maximum pulse volume:2.4cc The maximum heart rate:250bpm,200bpm at pulse volume>2.00cc. Internal Adult cuff volume:20cc Internal neonate cuff volume:300cc Blood pressure units: mmHg,kPa Heart Rate Accuracy:±1BPM Patient Conditions: Weak pulse, Tachycardia,Obese,Geriatric ±1%±1BPM Mild exercise±1.5%±1BPM Strenuous exercise±3%±1BPM Display 65k colors 4.3 inch TFT Display, brightness can be changed. Power AC100 - 240 V 50/60 Hz, 60 VA Environmental Conditions Working temperature: 15℃ to 40℃(59℉ to 104℉) Storage temperature: -20℃ to +65℃(-4℉ to +149℉) Relative humidity: < 90%,No condensation. Size (L x W x H) 27 cm x 26.5 cm x 13.2 cm Weight About 4kg Accessories: Power cord Fuse User 's Manual Buy safe products The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved International Buyer--Please note: Import duties,Taxes are not included in the item price.These charges are buyers' responsibility We are the manufacturer of medical equipment for 17 years, the following are our main products: ECG / ECG holter EEG / EEG Holter B-ultrasound Patient Monitor Fetal doppler Fetal Monitor Spo2 Monitor Stethoscope Medical Image.... Agent in the world! We are look for partners in the world now! Do you want to become our agent in you conutry? Join US! Skype:xuebox3 contec.med.mary at hotmail.com Only English User Manual,Please contact us if you need other language version.thank you
Price: 699 USD
Location: IL
End Time: 2024-07-19T06:05:20.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CON-TEC
MPN: 69450401
Model: MS200
Country/Region of Manufacture: China
Custom Bundle: No
Modified Item: No
Non-Domestic Product: No