Description: ONE ALC Automated Logic Corporation ZN341v+ Zone Controller Actuator Module Power-on LED error 30 Days Warranty- You are bidding on ALC Automated Logic Corporation ZN341v+ Zone Controller Actuator Module Power-on LED error. This unit power-on, initialize to run mode than LED error go solid red. No expertise to work on to troubleshoot this. SELLING AS-IS. Happy Bidding!!!Following Description is copied here from web;Automated Logic’s ZN341v+/ZN141v+ are designed for a variety of pressure-independent VAV applications. These advanced controllers feature an integral actuator, advanced precision air-flow sensor, flexible connectivity to the full line of RS sensors, and easy-to-use air balance routines. Sophisticated pre-engineered control algorithms reduce energy consumption, maximize actuator life, and ensure occupant comfort. The ZN series controllers are fully programmable and provide networked peer-to-peer communications using native BACnet-over-ARCNET 156 Kbps or MS/TP.Key Features and Benefits• Optimized design for all types of pressure independent VAV applications including cooling only, cooling with modulated hot water re-heat, cooling with electric re-heat, constant volume boxes and dual duct boxes.• Uses a high speed 16-bit microprocessor with 1 MByte Flash memory and 512 KByte of RAM for graphical programming, diagnostic trends, and easy firmware upgrades using remote downloading - no chip replacement necessary.• Built-in 0-10 V-dc AO for baseboard or re-heat valve actuator.• Compact and rugged design for easy mounting and an integral brushless actuator for reliability and longevity.• The combination of the precision air flow sensor and advanced VAV algorithm assures occupant comfort both at minimum and maximum design air flows, while maximizing actuator life.• Compatible with the ZASF integral air flow sensor/actuator assembly for dual duct applications.• Rnet port supports Automated Logic’s line of RS room sensors and provides local access to the system.• The ZN341v+/ZN141v+ controllers are fully graphically programmable and offer full peer-to-peer communications with other ZN line, ME line or SE line controllers. Graphical programs are universally understood and provide self-documenting control sequences.• Easy-to-use test and balance program via RS sensor or Rnet connection. BACnet Support: Conforms to the Advanced Application Controller (B-AAC) Standard Device Profile as defined in BACnet 135-2001 Annex L.Communication: The following ports are available on the ZN341v+/ZV141v+ modules: EIA-485 port for ARCNET 156 Kbps or MS/TP (9600 bps – 76.8 Kbps). Local access port for system start-up and troubleshooting. Rnet port for RS room sensors – the Rnet port supports up to four RS Standard sensors and one either RS Pro sensor or RS Plus sensor for averaging or high/low select control.Integral Air Flow Sensor: Precision low flow AWM series 0-2” W.C., sensitive down to ±0.001” W.C. Barbed tapered air flow connections 3/16” (4.75mm) I.D. tubing.Integral Actuator: Brushless DC motor, torque 35 inch-pounds (4Nm), 5 sq.ft. (0.46m²) maximum damper size. Both the ZN341v+ and ZN141v+ are compatible with the optional ZASF integral air flow sensor/actuator assembly for dual duct applications.Digital Outputs: ZN141v+ has one digital output, ZN341v+ has three digital outputs. Relay contact rated at 1A max @ 24V-ac/V-dc, configured normally open.Universal Inputs: Four inputs with 10 bit A/D resolution. Four inputs are configurable for dry contact and type 2 thermistors. Inputs 1 and 2 are also configurable for 0 to 5 V-dc. Inputs 3 and 4 are taken when a LogiStat sensor is connected – these inputs are available if RS sensors are used.Analog Outputs: One analog output, 0 to 10 V-dc (5mA maximum) with 8-bit resolution.Microprocessor: High speed 16-bit microprocessor with ARCNET communication co-processor.Memory: 512 KByte non-volatile battery-backed RAM, 1 MByte Flash memory, 16-bit memory bus. (Shelf life of the battery is 10 years with 10,000 hours of continuous operation.)Status Indicators: LED status indicators for EIA-485 communication, running, error, power and all digital outputs.Module Addressing: Rotary dip switches for intuitive network addressing of modules.Protection: Built-in surge and transient protection circuitry for communications.Listed by: UL916 (Canadian Std C22.2 No. 205-M1983), CE, FCC Part 15 – Subpart B – Class AEnvironmental Operating Range: 0ºF to 130ºF (-17.8ºC to 54.4ºC); 10 to 90% relative humidity, non-condensing. NOTE: Control modules must be installed within the building.Power Requirements: 24V-ac ± 10%, 26V-dc (25 V min, 30 V max),50 to 60Hz, 14 VAPhysical: UL94-5VA plenum rated enclosure.Weight: 1 lb. 11 oz. (0.8 kg)PicturesPay securely with any major credit card through PayPal!/font>
Price: 150 USD
Location: Denton, Texas
End Time: 2024-11-23T19:32:03.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Model: ZN341v+
Compatible Brand: For Airflow
Power Source: Electric
Type: VAV Air Control
MPN: ZN341v+
Item Weight: 1 lb
Brand: Automated Logic