Description: Package List: Needle Tips: 2/15 20 PC 4/25 20 PC 4/35 20 PC 1. Indications For user The Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm. The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success.60Pcs Dental Endo Sonic Irrigator Activator Tips For Root Canal Activator Clean Package List:Needle Tips:2/15 20 PC4/25 20 PC4/35 20 PC1. Indications For userThe Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm.The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success.2. Notice1) Remove the needle tip of EasyDO Activator. If your treatment process isover, please leave it for medical recycling.2) Please put exhaustively discharged battery into the recycling box.3)Do not submerge the unit in water.4)Do not autoclave the unit.3. Precautions1) The EasyDO Activator system is only used by dental professionals.2) The EasyDO Activator system is comprised of the Hand device and Activator needle tips of various sizes. If the system functions are used correctly, the equipment can maintain a normal operation. It is strictly prohibited to use non-original components, which will damage the equipment and make it unable to work normally. The original components include the Easydo activator hand device, needle tip and protective cover.The Easy smile reference number of the hand device EASYDO Activator-M10821The reference numbers of the EasyDOActivator Needle tipM10822-015 (Small)M10822-025 (Medium)M10822-035 (Large) 3)The handle device provides three speeds sonic motor adjustment options(High, Med, Low). The speed gears switch setting adjustment is ultimatelydetermined by the procedure to be performed, the cliniclan' experience canefficiently complete the clinical task.4) The handle device don’t require calibration for normal use.5) All clinical treatment should be performed with Easydo activatorprotective barrier sleeve that placed over the hand device.6) In the course of treatment, we should use sterilized and individuallypacked needle tip, otherwise it will cause root canal infection.7) It is necessary to use EasyDO Activator system correctly according totreatment specifications and operation manual to prevent injury to patients.8) Improper using of the hand device may result in broken handle of theequipment and damage of internal components.9) The EasyDO Activator needle tips and protective sleeve are intended forsingle-patient use only. Cross contamination may occur to the patient ifneedle tips and protective barriers are re-used. 4. Warranty information of EasyDO activator1)TheEASYINSMILEcompanyprovidesuserswithqualityassurance withinoneyearfromthedateofpurchaseofthisproduct.In caseofanyfailureduetothedefectof Handdevice materialorproductionprocessofthemainframe withinthisyear,the EASYINSMILE companywill provideequipmentrepairorreplacementproducts.2)Thewarrantydoesnotinclude consumablessuchasneedles, batteries,etc.3)Iftheequipmentisdamagedduetoimproperuseandmaintenance,ormaintenancepersonnel repairorchange ofsparepartswithouttheauthorizationofEASYINSMILE, thewarrantypolicyisinvalid.4)Underanycondition,neitherEASYINSMILE noritsaffiliatesareresponsibleforanyspecial,incidental,orconsequentialliabilityresultingfromaviolationofthewarrantypolicy,contract,oranyotherlegalpolicy.Such damagesincludebutarenotlimitedtolossofinvestment,lossofprofits,losscausedbywronguseofproductfunctions,etc.;includingbutnotlimitedtothirdpartyclaimsandincreaseofservicecostcausedbyanyalternativeequipment,etc.5)WarrantylimitationsContentnotcoveredbywarranty:-Needle tip-Handdevicebarrier sleeve-Damagecausedbymisuse,abuse,neglectofpromptorchange of theequipmentusage-Normalwearandotherexternalscratches,includingscratches,wear,cracks,discolorationorfade.-Batteryreplacement*Note:Iftheproductisnotusedforalongtime(twoweeksorlonger),pleaseremovethebattery.Italsomustberemovedduringtransport,forexample,duringdelivery10) Properly dispose the Activator needles tip and hand device protectivebarriers in accordance with the local laws and regulations and environmentalprotection requirements.11) Dispose the battery after being used in accordance with the local lawsand regulations and environmental protection requirements, when battery isexhausted.12) The hand device must be repaired if necessary according to the directionof the manufacturer.13) Don’t insert needle tip into the hand device. If the equipment is not usedfor a long time, placing the hand device into packing box is recommended.14) Remove the battery when the hand device is not used for a long time.15) The hand device can be kept at the temperature of 0 ℃ ~ 55 ℃,relative humidity 0% ~ 75% RH and air pressure750-1060 HPA.16) The hand device should be keep away from strong electromagneticinterference, which may affect the performance and normal use of handdevice.17) The hand device should be kept away from portable or mobile RFcommunication devices, which may affect the performance of hand device .18) The hand device could not be adjacent to or stored with other equipment.In addition, it is necessary to check regularly whether the hand device canwork normally.19)Properdisposalofthehand device isrequired whenthehand pieceisdeemedno-functional inaccordancewithlocallawsandregulations.6.Product parametersNameEasyDO ActivatorModelEASYDO Activator-M1082FunctionDebridement / disinfection / root canal therapyUse environmentIndoor environment; Temperature range: 0 ℃ ~ + 55 ℃; RelativeHumidity: 0% ~ 75% RH; Air Pressure: 750-1060 HPAPower SupplyDC:1.0v~1.5vBatteryAA grade LR6, 1.5v mercury-free alkaline dry batterySizeL 183mm * W 23mm * H43.1mmGross Weight124g7.Operation / StepPreparation:1)Preparetherootcanaltoproduceafullytaperedshape.2)FillpupchamberwithNaOCI,EDTA,orfinalrinsesoulution.3)Selecttheneedletipthatmanuallyfitslooselywithin2mmof theworkinglength.4) Placethebarriersleeveover thecompletelengthofthehanddevice.5)Connecttheneedletiptothehand device withthebarrier sleeve.Theactivatorshouldsnaponfirmly,promotingasecureconnectionwiththehanddevice.6)PressON/OFF buttonfor 1 second,youcanseethebatterypowerstatus.Ifthepowerisenough,youcancontinuethetreatment.Ifthepowerisnotenough,youneedtoreplacethebattery.7)Placetheattachedneedle tip intothepreparedrootcanal.8)DrepresstheON/OFFbutton toactvate.Switchdefaultstohighspeeduponactivation. Depress the3-speedswitchtoselectmediumspeedorlowspeed.9)Useapumpingactiontomovethehanddevice inshort2~3mmverticalstrokes.10)Hydrodynamicallyagitatethemedicalsolutionforabout30-60seconds.11)Afterwashing,useasuctionpipetoremoveloosedebrisandsundries fromtherootcanal.12)Repeattheabovestepsforeachdifferentrootcanaltreatment.*whentheclinicalprocedurehasbeencompleted,remove theprotectivebarrier sleeve,removetheneedle tip andstoreitin themedicalwasterecyclingbox. The needle tip andprotectivesleeve areintendedforsingle-patientused only.Otherinstructions:iftheEasyDOActiver handdevicehasbeenworkingfor8minuteswithoutanyoperation,orthereisnooperationaftertheequipment stopsworking,itwillenterthestateofself-protectionsystemandpoweroFF. Ifyouneedittorestart ,pleasedepresstheON/OFFswitch.8. Key points of Operation:5.1)POWER OF BATTERY STATUSDepressthe" ON /OFF Switch"keyfor1secondtoobservethe"PowerIndicator"statusaroundthebuttonof thehanddevice.1. Ifthe"PowerIndicator"iswhite,itmeanstheactivatorsystemisinfullpowerstatus;2. ifthe"PowerIndicator"isredandwhite,itmeansthesystemisinhalfpowerstatus;3. ifthe"PowerIndicator"isred,itmeansthesystemisinpowershortagestatus;4. Ifthe"PowerIndicator"isflashingred,itindicatesthatthesystemisonthevergeofpowerfailure.5. Please noteifthe"powerindicator"isflashingred,pleasereplacethebattery. BrandEasyinsmileCountry/Region of ManufactureChinaIntended Use/DisciplineDental Laboratory, Dentistry, Endodontics, OrthodonticsMPNDoes not applyModelendo irrigator activator tipsUltrasonic Scaler TypehandheldWarehouseUSA/ChinaCustom BundleYesBundle DescriptionEasyinsmile packageSize02/15 04/25 04/35
Price: 54.63 USD
Location: Rowland Heights, California
End Time: 2023-10-15T16:50:49.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Easyinsmile
Country/Region of Manufacture: China
Intended Use/Discipline: Dental Laboratory, Dentistry, Endodontics, Orthodontics
MPN: Does not apply
Model: endo irrigator activator tips
Ultrasonic Scaler Type: handheld
Warehouse: USA/China
Custom Bundle: Yes
Bundle Description: Easyinsmile package
Size: 02/15 04/25 04/35